Chapter 7: Event Log and Syslog Servers

108

Configuring the Syslog Server

This section about the syslog server contains the following procedures:

ˆ

“Configuring the Syslog Server’s IP Address,” next

ˆ

“Setting the Syslog Facility Code” on page 108

Configuring the

Syslog Server’s

IP Address

The chassis can only use the 10/100Base-TX port on the AT-CV5M01
Management Card to send out the packets to the sysLog server.

When configuring a Syslog Server Address, the following guidelines apply:

ˆ

The 10/100Base-TX port on the AT-CV5M01 Management Card must
be connect to the network.

ˆ

The AT-CV5M01 Management Card must be assigned an IP address
and subnet mask.

ˆ

The AT-CV5M01 Management Card must be assigned a default
gateway if a router separates the management card from the remote
device being pinged.

ˆ

The syslog server must reachable through the same subnet as the
10/100Base-TX port on the AT-CV5M01 Management Card.

To specify the IP address of a syslog server, perform the following
procedure:

1. From the Main Menu, select Administration.

The Administration Menu is displayed, as shown in Figure 6 on page
38.

2. From the Administration Menu, select Syslog Server Address field

and enter the IP address of the syslog server.

3. Press .

The syslog server IP address is displayed.

4. From the Main Menu, select System Configuration.

The System Configuration Menu is displayed, as shown in Figure 10
on page 46
.

5. From the System Configuration Menu, select Save Configuration

File.

Setting the Syslog

Facility Code

This feature adds a facility code to the entries when they are sent to the
syslog server. The facility level is a way for you to add a numerical code to
each entry to help you group entries on the syslog server according to the