background image

25-34

User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

Chapter 25

The switch always services the queue that has the highest accumulated
weight
. If two queues have the same accumulated weight, the switch first
services the queue that has the highest priority (0 – 7).

Table 25-19

lists the default weight increment for each queue.

For information on how to set up WFQ, see “

Setting Up WFQ

” later in this

chapter.

Example

Suppose that the accumulated weight of all queues is set at their weight
increments.

1. The switch services queue 7 because its accumulated weight is 128.

2. The accumulated weight of queue 7 is reset to 128, and the accumulated

weight of all other queues is increased by their weight increment.

At this point, queue 7 and queue 6 both have an accumulated weight of
128.

3. The switch services queue 7 because it is the higher priority queue.

4. The accumulated weight of queue 7 is then reset to 128, and the

accumulated weight of all other queues is increased by their weight
increment.

Now queue 6 has an accumulated weight of 192, and queue 7 has an
accumulated weight of 128.

5. The switch services queue 6 because it has the higher accumulated

weight.

Table 25-19. Default Weight Increments

Queue

Weight Increment

WFQ 0

1

WFQ 1

2

WFQ 2

4

WFQ 3

8

WFQ 4

16

WFQ 5

32

WFQ 6

64

WFQ 7

128