Document No. 10-300077, Issue 2

10-17

Configuring Redundancy Options

4. Click SYNCHRONIZE to start the synchronization process.

If both supervisors are running v6.0 or later application software, the
switch performs the following checks after you synchronize the active
and standby supervisors:

Version of application software.

Startup image (app 1, app 2, cardapp 1, or cardapp 2)

If any of these settings changed during the synchronization, the standby
supervisor module automatically resets so that it is failover-ready. In
earlier versions of software, you had to manually reset the standby
supervisor, if these settings changed.

*Important: If you are updating the boot code, you must manually

reset the standby supervisor after synchronizing it
with the active supervisor.

* Note: For this automatic reset feature to work, the active and standby

supervisors must both be running v6.0 or later application
software. The first time that you synchronize the supervisor
modules after upgrading the active supervisor from v5.x
application software to v6.x, you must manually reset the
standby supervisor.

CLI Command

To synchronize the active and standby supervisor modules, use the
following CLI command:

(configure)#

cpu_redundancy synchronize

APP1

Version - Displays the version of the image in

application 1 (APP1) for each supervisor module.

Checksum - Displays the checksum for the image

running in APP1.

APP2

Version - Displays the version of the image in

application 2 (APP2) for each supervisor module.

Checksum - Displays the checksum for the image in

APP2.

Startup Config

Date/Time Modified - Displays the date and time that

the configuration (startup.txt) was modified.

Checksum - Displays the checksum for the image in the

Startup Config.

Table 10-2. CPU Redundancy Status Web Page Fields

Parameter

Definition

2 of 2