Configuring Ports

Internal-error-config enabled on port 7/1

Internal-error-config enabled on port 7/2

Internal-error-config enabled on port 7/3

Internal-error-config enabled on port 7/4

Feature enabled for port(s) specified

If CRC Error Threshold is exceeded then port

will automatically be shut down.

TRAFFIC LOSS WILL RESULT if no redundant port

is configured and port shutdown occurs.

To UNDO use: "set port internal-error-

shutdown {slot/port} disable"

Upon Failure:

The set port internal-error-shutdown all-ports disable command
produces system messages similar to the following:

Upon Success:

Internal-error-config disabled on port 3/1

Internal-error-config disabled on port 3/2

Internal-error-config disabled on port 4/1

Internal-error-config disabled on port 4/2

Internal-error-config disabled on port 4/3

Internal-error-config disabled on port 4/4

Slot 6 has 10/100 ethernet ports that are

unsupported and will not be set.

Internal-error-config disabled on port 7/1

Internal-error-config disabled on port 7/2

Internal-error-config disabled on port 7/3

Internal-error-config disabled on port 7/4

Feature disabled for port(s) specified

Port(s) will not be shut down if CRC Threshold

Exceeded.

Upon Failure:

Don’t Shutdown all ports failed

The set internal-error-threshold <5-500> command produces
system messages similar to the following: