10-14

User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

Chapter 10

CAUTION:

* Note: If the standby supervisor becomes active, it assumes the IP and

MAC addresses of the previously active supervisor.

* Note: When a standby supervisor is installed in the switch there is a

45-second wait period before the standby supervisor is fully
initialized.

Do not remove the standby supervisor module during initialization.

One Supervisor module
in slot 2

The slot 2 supervisor module is active.

If a supervisor module is inserted into slot 1, the slot
2 supervisor module remains active and sends health
reports to the standby supervisor in slot 1.

If the slot 2 supervisor is removed, reset, or fails, or if
the switch is reset, the slot 1 supervisor becomes the
active supervisor, and the slot 2 supervisor becomes
the standby. The slot 1 supervisor then sends health
reports to the slot 2 standby supervisor.

Supervisor modules in
slot 1 and slot 2

The slot 1 supervisor module is active and sends
health reports to the standby supervisor in slot 2.

If the slot 1 supervisor module is removed, reset, or
fails, the slot 2 supervisor becomes the active
supervisor. If you then replace the slot 1 supervisor, it
remains the standby supervisor and receives health
reports from the active supervisor in slot 2.

If the slot 2 supervisor is removed, reset, or fails, or if
the switch is reset, the slot 1 supervisor becomes the
active supervisor, and the slot 2 supervisor becomes
the standby. The slot 1 supervisor then sends health
reports to the slot 2 standby supervisor.

Note:

If the switch is reset, slot 1 supervisor is the

active supervisor, unless it has failed.

Table 10-1. Supervisor Module Configurations

Configuration

Active and Standby Role

2 of 2