Setting the temperature system, Web agent procedure, Setting the temperature system -13 – Avaya 580 User Manual
Page 107
Document No. 10-300077, Issue 2
3-13
Configuring System Information
Setting the Temperature System
You can set the upper and lower temperature warning systems for the switch
backplane and slot 1. These warning systems cause the following to happen
if the temperatures you set are reached:
■
Shutdown Temperature—The switch shuts down if this
temperature is reached.
■
Upper Warning Temperature—The switch generates an alarm if
this temperature is reached. If the Shutdown Temperature is
reached, once the temperature drops below the Upper Warning
Temperature, the switch restarts.
■
Lower Warning Temperature—The switch generates an alarm if
this temperature is reached. Once the temperature rises above this
temperature, the alarm is cleared.
■
Low Limit Temperature—The switch generates an alarm if this
temperature is reached.
for the default temperature system settings. You can set the
temperature system using either the Web Agent or the CLI.
Web Agent
Procedure
To configure the temperature warning systems:
1. In the navigation pane, expand the System > Configuration folders, and
then click Temperature System. The Temperature System Web page is
displayed in the content pane. See
.
Figure 3-7. Temperature System Web Page for P580