beautypg.com

Cli command – Avaya 580 User Manual

Page 108

background image

3-14

User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

Chapter 3

2. In the Slot 1 Sensor and Backplane Sensor fields, enter the desired

temperature warnings.

* Note: The P882 does not display the current temperature of the

backplane. In the Current Temperature field, the switch
displays

--

.

* Note: If a redundant Supervisor module is installed, the Slot 2 Sensor

column displays.

* Note: You cannot change settings for the backplane temperature

sensors on the P882. If you attempt to change the settings, the
switch displays the following error message:

Set Limits for Backplane Sensor failed -

failure writing to sensor

3. In the CPU Sensor fields, enter the desired temperature warnings.

4. Click APPLY to save your changes, or DEFAULTS to reset the fields to

their default settings.

5. If you change the temperature ranges for the active supervisor, you must

synchronize the active and standby supervisors to copy the temperature
settings to the standby supervisor.

CLI Command

To check the temperature status, use the show temperature CLI command.

To set the temperature thresholds, use the following CLI commands:

(configure)#

set temperature {supervisor-slot | backplane-

sensor | cpu-sensor | probe} shutdown

(configure)#

set temperature {supervisor-slot | backplane-

sensor | cpu-sensor | probe} warning {upper | lower | low-limit}

This manual is related to the following products: