beautypg.com

Replacing an element, Web agent procedure, Replacing an element -9 – Avaya 580 User Manual

Page 309

background image

Document No. 10-300077, Issue 2

10-9

Configuring Redundancy Options

WARNING:

Replacing an Element

If an element fails, you are notified by:

An event log message

An error message that displays in the Switch Elements field

To replace a failed element:

1. Disable redundant hardware.

2. Copy the running config to the startup config.

3. Synchronize if you have redundant supervisor modules.

4. Power off the switch power supplies.

To avoid bodily harm and equipment damage, you must power off the
switch before you remove switch controllers or elements.

5. Power on the switch power supplies and login.

6. Enable the redundant hardware (see “

Enabling Redundant Hardware

earlier in this chapter).

7. Replace the failed element.

8. Power on the switch’s power supplies and login.

Web Agent
Procedure

To enable the replacement element using the Web Agent:

1. In the navigation pane, expand the System > Configuration folders, and

then click Switch Fabric. The Switch Fabric Status Web page is
displayed in the content pane. See

Figure 10-5

.

2. Select Yes from the Configure Redundant Hardware field pull-down

menu.

3. Click APPLY to enable the redundant element.

The Switch Elements field displays:

Normal # 0

This indicates that the redundant element is now enabled.

4. Save the configuration changes