10-10

User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

Chapter 10

CLI Command

To enable an element using the CLI, enter the following command from
Configure mode:

>

set fabric configure-redundant-hardware enable

Configuring Supervisor Module Redundant
Ethernet Console IP Addresses

Web Agent
Procedure

If you need to communicate with both the Active and Standby Supervisors,
configure an alternate Ethernet Console IP address for both. Configure an
alternate IP address for both slot 1 and 2 CPU’s, by using the Web Agent or
the CLI.

* Note: Do not Login to a Standby Supervisor module to manage the

switch. The Standby Supervisor does not have accurate switch
status information until it becomes the Active Supervisor.

To identify the Active or Standby supervisor, look at the LED
display (marquee), or open the System > Configuration >
CPU Redundancy > Status/Statistics
folders from the Web
Agent, or use the show CPU status

CLI command.

To configure a redundant console IP address by using the Web Agent:

1. In the navigation pane, expand the System > Configuration > CPU

Redundancy folders, and then click Configuration. The CPU
Redundancy Configuration Web page is displayed in the content pane.
See

Figure 10-6

.

Figure 10-6. CPU Redundancy Configuration Web Page