Cli command, Web agent procedure – Avaya 580 User Manual
Page 310
10-10
User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Chapter 10
CLI Command
To enable an element using the CLI, enter the following command from
Configure mode:
>
set fabric configure-redundant-hardware enable
Configuring Supervisor Module Redundant
Ethernet Console IP Addresses
Web Agent
Procedure
If you need to communicate with both the Active and Standby Supervisors,
configure an alternate Ethernet Console IP address for both. Configure an
alternate IP address for both slot 1 and 2 CPU’s, by using the Web Agent or
the CLI.
* Note: Do not Login to a Standby Supervisor module to manage the
switch. The Standby Supervisor does not have accurate switch
status information until it becomes the Active Supervisor.
To identify the Active or Standby supervisor, look at the LED
display (marquee), or open the System > Configuration >
CPU Redundancy > Status/Statistics folders from the Web
Agent, or use the show CPU status
CLI command.
To configure a redundant console IP address by using the Web Agent:
1. In the navigation pane, expand the System > Configuration > CPU
Redundancy folders, and then click Configuration. The CPU
Redundancy Configuration Web page is displayed in the content pane.
See
.
Figure 10-6. CPU Redundancy Configuration Web Page