Configuration guidelines, Figure 11-5 – H3C Technologies H3C WX6000 Series Access Controllers User Manual
Page 92
11-5
Figure 11-5 Configure Device as the NTP server of AC
Type 24 in the ID box, and type aNiceKey in the Key String text box for key 1.
Type 1.0.1.11 in the NTP Server 1 text box and type 24 in the Reference Key ID text box.
Click Apply.
3) Verify the configuration
After the above configuration, you can see that the current system time on Device is the same with that
on AC.
Configuration Guidelines
When configuring system time, note that:
A device can act as a server to synchronize the clock of other devices only after its clock has been
synchronized. If the clock of a server has a stratum level higher than or equal to that of a client’s
clock, the client will not synchronize its clock to the server’s.
The synchronization process takes a period of time. Therefore, the clock status may be
unsynchronized after your configuration. In this case, you can refresh the page to view the clock
status and system time later on.