Normal WLAN mesh deployment

1) Normal FIT MP scenario

Figure 32-2 Normal FIT MP scenario

As shown in

Figure 32-2

, two mesh networks are controlled by the same AC. At least one MPP in a

mesh has wired connectivity with the AC. When an MP comes up, it scans the network and forms

temporary connections with all available MPs in its vicinity. Such temporary connections allow the MP to

connect to the AC for downloading its configurations. After downloading its configurations from the AC,

the MP will establish secure connections with neighbors sharing the same preshared key.

2) One FIT MP with two radios, each on a different mesh