Figure 11-3 – H3C Technologies H3C WX6000 Series Access Controllers User Manual
Page 90
11-3
Figure 11-3 Network time configuration page
shows the network time configuration items.
Table 11-1 Network time configuration items
Item
Description
Clock status
This field displays the synchronization status of the system clock.
Local Reference Source
Set the IP address of the local clock source to 127.127.1.u, where u ranges
from 0 to 3, representing the NTP process ID.
If the IP address of the local clock source is specified, the local clock is
used as the reference clock, and thus can provide time for other devices.
If the IP address of the local clock source is not specified, the local clock is
not used as the reference clock.
Support for this configuration item depends on the device model.
Stratum
Set the stratum level of the local clock.
The stratum level of the local clock decides the precision of the local clock. A
higher value indicates a lower precision. A stratum 1 clock has the highest
precision, and a stratum 16 clock is not synchronized and cannot be used as a
reference clock.
Support for this configuration item depends on the device model.
Source Interface
Set the source interface for an NTP message.
If you do not want the IP address of a certain interface on the local device to
become the destination address of response messages, you can specify the
source interface for NTP messages, so that the source IP address in the NTP
messages is the primary IP address of this interface. If the specified source
interface is down, the source IP address is the primary IP address of the
egress interface.