beautypg.com

Fim performance limits, Fim performance limits -23 – Rockwell Automation 1757-SWKIT4000 ProcessLogix R400.0 Installation and Upgrade Guide User Manual

Page 275

background image

Publication 1757-IN040B-EN-P - March 2002

Performance and Capacity Specifications 11-23

FIM Performance Limits

The FIM is a complex device interfacing the high-speed ProcessLogix
internal networks to the 31.25 Kbps FF H1 links. It uses an advanced
caching scheme to maintain quick response to reasonably fresh values
and maintains communications with the multiple FF devices as time
permits in the prioritized scheme of the Link Schedule based on FF
specification requirements. This table describes limits of performance
through the FIM.

The FIM cache (one for both links) holds 800 items. An item can be:

A simple parameter

A structured parameter

An arrayed parameter

Quality of service is based on priorities. Priorities of service are
(highest to lowest)

Incoming H1 Subscriptions and outgoing H1 Publications, per
LAS

H1 Alerts

H1 Writes

New H1 reads (and re-written parameters)

H1 Re-reads to refresh the cache

PROFIBUS Device Profiles Supported
(with custom function blocks)

PROFIDRIVE, Encoder

Devices supported with custom function blocks

Siemens Simatic ET200M I/O, Siemens Simocode

3UF5 Motor Protection and Control Unit

Data types supported by the “Generic” PROFIBUS
Channel Blocks

(1)

Single bit (Discrete),
8 bit signed/unsigned integer,
16 bit signed/unsigned integer,
32 bit signed integer

(1)

The “generic” function blocks are capable of communicating with various PROFIBUS devices. The data types required/supplied by

the device are a consideration in the determination of whether or not a specific device can be used with these blocks.

Table 11.O Profibus Capacity/Topology Specifications

PFB Module and PROFIBUS Block Specifications