beautypg.com

Discovering emc clariion storage systems, Discovering emc clariion, Storage systems – HP Storage Essentials NAS Manager Software User Manual

Page 96

background image

Discovering NAS Devices, Tape Libraries, Switches and Storage Systems

64

If the cimom.symmetrix.exclude property, the management server discovers and obtains

details from all EMC Symmetrix Storage Systems managed by discovered Solutions Enablers.

IMPORTANT:

The IP addresses of excluded elements appear in the discovery (Tools > Storage

Essentials

> Home > Discovery > Setup), topology (Tools > Storage Essentials > Home >

Discovery

> Topology), Discovery Data Collection (Options > Storage Essentials >

Discovery

> Run Discovery Data Collection), or Get Details lists (Tools > Storage Essentials

> Home > Discovery > Details). The management server does not display additional information

about excluded elements in the user interface. The management server, however, does mention in

the logs (Discovery > View LogsTasks & Logs > View Storage Essentials Log) that a

provider instance has been created for an excluded element. You can ignore this message that

appears in the logs.

To modify the cimom.symmetrix.exclude property:

1.

Select Options > Storage Essentials > Manage Product Health. Then, click Advanced in

the Disk Space tree.

2.

Click Show Default Properties at the bottom of the page.

3.

Copy the following command. How you copy the text depends on your Web browser. If you

are using Microsoft Explorer or Netscape Navigator, select the text and then right-click the

selected text. Then, select Copy.

#cimom.symmetrix.exclude=000183500570,000183500575

4.

Return to the Advanced page.

5.

Paste the copied text into the Custom Properties field. How you paste the text depends on

your Web browser. If you are using Microsoft Explorer or Netscape Navigator, right-click the

field and select Paste.

6.

Make sure the property is not commented out by removing the hash (#) symbol in front of the

property. Add the serial numbers corresponding to the Symmetrix storage systems you want to

exclude from discovery. Separate additional serial numbers with a comma, as shown by the

following example:

cimom.symmetrix.exclude

=000183500570,000183500575

where 000183500570 and 000183500575 are serial numbers for Symmetrix storage

systems.

7.

When you are done, click Save.

8.

Restart the service for the management server for your changes to take effect.
While AppStorManager is restarting, users are not able to access the management server. The

AppStorManager service must be running for the management server to monitor elements.

Discovering EMC CLARiiON Storage Systems

The EMC Navisphere® CLI must be installed on the management server for the management server

to communicate with the CLARiiON® storage system. At the time this documentation was created,

EMC distributed the Navisphere CLI as part of the EMC Navisphere Software Suite. Contact your

EMC representative for more information about obtaining the Navisphere CLI. Distribution rights