Discovering emc clariion storage systems, Discovering emc clariion, Storage systems – HP Storage Essentials NAS Manager Software User Manual
Page 96
Discovering NAS Devices, Tape Libraries, Switches and Storage Systems
64
If the cimom.symmetrix.exclude property, the management server discovers and obtains
details from all EMC Symmetrix Storage Systems managed by discovered Solutions Enablers.
IMPORTANT:
The IP addresses of excluded elements appear in the discovery (Tools > Storage
Essentials
> Home > Discovery > Setup), topology (Tools > Storage Essentials > Home >
Discovery
> Topology), Discovery Data Collection (Options > Storage Essentials >
Discovery
> Run Discovery Data Collection), or Get Details lists (Tools > Storage Essentials
> Home > Discovery > Details). The management server does not display additional information
about excluded elements in the user interface. The management server, however, does mention in
the logs (Discovery > View LogsTasks & Logs > View Storage Essentials Log) that a
provider instance has been created for an excluded element. You can ignore this message that
appears in the logs.
To modify the cimom.symmetrix.exclude property:
1.
Select Options > Storage Essentials > Manage Product Health. Then, click Advanced in
the Disk Space tree.
2.
Click Show Default Properties at the bottom of the page.
3.
Copy the following command. How you copy the text depends on your Web browser. If you
are using Microsoft Explorer or Netscape Navigator, select the text and then right-click the
selected text. Then, select Copy.
#cimom.symmetrix.exclude=000183500570,000183500575
4.
Return to the Advanced page.
5.
Paste the copied text into the Custom Properties field. How you paste the text depends on
your Web browser. If you are using Microsoft Explorer or Netscape Navigator, right-click the
field and select Paste.
6.
Make sure the property is not commented out by removing the hash (#) symbol in front of the
property. Add the serial numbers corresponding to the Symmetrix storage systems you want to
exclude from discovery. Separate additional serial numbers with a comma, as shown by the
following example:
cimom.symmetrix.exclude
=000183500570,000183500575
where 000183500570 and 000183500575 are serial numbers for Symmetrix storage
systems.
7.
When you are done, click Save.
8.
Restart the service for the management server for your changes to take effect.
While AppStorManager is restarting, users are not able to access the management server. The
AppStorManager service must be running for the management server to monitor elements.
Discovering EMC CLARiiON Storage Systems
The EMC Navisphere® CLI must be installed on the management server for the management server
to communicate with the CLARiiON® storage system. At the time this documentation was created,
EMC distributed the Navisphere CLI as part of the EMC Navisphere Software Suite. Contact your
EMC representative for more information about obtaining the Navisphere CLI. Distribution rights
- Storage Essentials Report Designer Software Storage Essentials Global Reporter Software Storage Essentials Exchange Viewer Software Storage Essentials Chargeback Manager Software Storage Essentials Enterprise Edition Software Storage Essentials File System Viewer Software Storage Essentials Backup Manager Software Storage Essentials Provisioning Manager Software