Page 489

background image

Storage Essentials 5.1 User Guide 457

Event Manager does not display events from Brocade switches with the firmware version 3.0.

This firmware version is not supported by Event Manager. You can, however, specify Event

Manager not to display events from additional firmware versions. See

Filtering Events

” on

page 464.

Events from Brocade Fabric Watch have “Fabric watch:” in their heading, as shown in the

following example:

Fabric watch: threshold is below low boundary, Value:30 Class: Environment
ClassArea: Temperature Index: 1 EventType: Below EventState: Faulty

Issues with McDATA and Connectrix Switches

If you discovered McDATA and/or Connectrix switches through SWAPI, Event Manager does

not report events for switch hardware failures, except for those regarding switch ports (port

off-line/port online).

If you are not receiving events from McDATA and Connectrix switches discovered through

SNMP, make sure you have the correct port set for receiving SNMP traps. You must also

configure the proxy or each switch (depending on your configuration for discovery) to send the

SNMP traps to the correct port on the management server. See ”

Discovering McDATA and

EMC Connectrix Switches

” on page 45 for more information.

If you want the management server to receive SNMP events from Connectrix or McDATA

switches, do one of the following:
• If you discovered Connectrix Manager or EFC Manager, only enable SNMP trap

forwarding to the management server on the Connectrix Manager or EFC Manager, not on

the individual switches. Connectrix Manager or EFC Manager should be configured to

forward SNMP traps to the IP address of the management server, and the community string

should match the user ID you used to discover Connectrix Manager or EFC Manager.

• If you discovered Connectrix or McDATA switches directly, enable SNMP trap forwarding

on the switches, not on any other management software. The switches should be configured

to forward SNMP traps to the IP address of the management server, and the community

string should match the user ID you used to discover the Connectrix or McDATA switches.

Viewing Event Details

To access event details:

1.

Access Event Manager as described in

About Event Manager

” on page 453.

2.

Do one of the following in Event Manager:
• Right-click an event, and select Event Details from the drop down menu, as shown in the

following figure:

Figure 62

Right-clicking Event Details