Brocade smi-s provider installation requirements, New installations of the management server), Verifying brocade rapid program is set to 1 – HP Storage Essentials NAS Manager Software User Manual

Page 67

background image

Storage Essentials 5.1 User Guide

35

IMPORTANT:

When using the Brocade Fabric Access API, Brocade recommends that the switch

with the most recent version of Brocade API firmware (newer than v.2.6.x) is configured as the

proxy switch.

When discovering Brocade SMI-S hosts the IP address of the Brocade SMI-S proxy server must be

entered for Discovery Step 1. Be sure to see the Support Matrix for the latest details on firmware

requirements.

Brocade SMI-S Provider Installation Requirements

(New Installations of the Management Server)

If this is a new installation of the management server, the management server is configured to

discover Brocade switches through SMI-S, by default, as noted earlier. You must first download

and install the Brocade SMI-S provider software from the following site:

ftp://ftp.compaq.com/pub/products/storageworks/smisproviders/brocade_provid
er.pdf

Be sure to check this FTP site periodically to be sure you are running a current version of the

Brocade SMI-S provider. See the Support Matrix for details.
Keep in mind the following for Brocade SMI-S switches:

You must verify that the Rapid program on the switch is set to 1. Rapid must be set to 1 so that

the management server or any Brocade SMI-S agent can communicate with the switch. Be sure

to see

Verifying Brocade Rapid Program Is Set to 1

” on page 35 for more information. Note

that this requirement also applies to Brocade switches that are configured to use the Fabric

Access API provider.

Before performing any provisioning operations that involve a Brocade switch after an upgrade

to build 4.2 or 5.1 from any build prior to 4.2, you must perform Discovery Data

Collection/Get Details for any subset of elements that includes this Brocade switch. See ”

Step 4

- Discovery Data Collection or Get Details

” on page 90 for details on running Discovery Data

Collection/Get Details.

Verifying Brocade Rapid Program Is Set to 1

If you are discovering Brocade switches or Brocade SMI-S agents, verify that the Rapid program on

the switch is set to 1.

1.

(Optional) Set the command prompt window so that it displays many rows.
While completing the following steps, the command prompt window displays a large amount of

data. You might want to expand the size and buffer of the command prompt window. To do

this in Microsoft Windows 2000, click the upper-right corner of the command prompt window,

click the Layout tab, and then modify the options under Screen Buffer Size and Window Size.

2.

Access the Brocade switch or SMI-S agent by using the telnet option. For example,

telnet

open 10.1.213.228

where 10.1.213.228 is the IP address of the switch.