beautypg.com

Discovering sun storedge 3510 storage systems, Discovery from hp sim, Discovering sun storedge – HP Storage Essentials NAS Manager Software User Manual

Page 108: 3510 storage systems

background image

Discovering NAS Devices, Tape Libraries, Switches and Storage Systems

76

11.

Click OK.

12.

To start discovering elements on the network, click the Start Discovery button on the IP

Addresses tab.

Discovering Sun StorEdge 3510 Storage Systems

Before you can discover a Sun StorEdge 3510 storage system, you must set up a Sun StorEdge

3510 SMI-S provider and a Sun StorEdge™ Configuration Service. The provider cannot be

installed on the same computer as the management server due to a port conflict.
The Sun StorEdge™ Configuration Service can be installed in one of the following locations:

on the same computer as the Sun StorEdge 3510 SMI-S provider

on the management server

on a separate computer

To install the Sun StorEdge™ Configuration Service you must install the following packages:

Sun StorEdge™ Configuration Service Console (SUNWscsu)

Sun StorEdge™ Configuration Service Agent (SUNWscsd)

Sun StorEdge™ Diagnostic Reporter Agent (SUNWscsa)

You must also install the following packages. Contact Sun technical support for information on how

to obtain and configure these packages.

WBEM Solutions J WBEM Server 1.0

Sun StorEdge™ CIM/WBEM Provider SDK (SUNWagsdk package) - A readme file is installed

as part of SUNWagsdk package. Follow the instructions in that readme file.

Sun StorEdge™ 3510 SMI-S Provider (SUNW3x10a package) - A readme file is installed as

part of SUNW3x10a package. Follow the instructions in that readme file.

To discover Sun StorEdge 3510 storage systems, you must discover the Sun StorEdge 3510 SMI-S

provider. To discover a Sun StorEdge 3510 storage system, you must enter the following

information for the instance of the Sun StorEdge 3510 SMI-S provider.

user name and password used for the system running Sun StorEdge 3510 SMI-S provider

IP address of the system running Sun StorEdge 3510 SMI-S provider

IMPORTANT:

The management server is unable to display logical volumes configured on Sun

StorEdge 3510 storage systems. Any logical volumes as well as the logical drives that comprise

them will not appear in the UI. There will be no indication that this happened.

Discovery from HP SIM
To discover Sun StorEdge 3510 storage systems, provide the following information in HP Insight

Manager:

IP address or system name of the system running the Sun StorEdge 3510 SMI-S provider you

want to discover. See

Adding an IP Range for Scanning

” on page 24 or

Adding a Single IP

Address or DNS Name for Discovery

” on page 25 for more information.