beautypg.com

HP Storage Essentials NAS Manager Software User Manual

Page 442

background image

Path Provisioning

410

The Path Provisioning screen with changes from executed jobs. After a job is executed in Path

Provisioning, the Path Provisioning screen is not updated until you click the Refresh button or

you exit and re-enter Path Provisioning.

Adding a volume to an existing host security group on an EMC Symmetrix or DMX array only

performs the masking operation, but it does not map the port on the array. The native tools for

the array show that the masking to the host initiator took place, but the volume is still not

mapped to a storage port.

Other parts of the product, such as:
• Application Viewer
• Capacity Manager
• Performance Manager
• Backup Manager
• Provisioning Manager
• System Manager

Keep in mind the following:

Path Provisioning runs within a Java applet. If you receive “out of memory” messages when you

view Path Provisioning, you may need to increase the amount of memory assigned to the Java

plug-in on the client computer.

If you select a direct attached host, the storage ports appear in the LUN pane with a

next

to them, indicating they are unreachable. You can still select these storage ports that have a

next to their icon and schedule the job. These storage ports are shown as unreachable in

the user interface because the user interface uses switches to display the association between a

host and a storage system. If the management server cannot detect a switch, as with a DAS

connection, the user interface assumes the storage ports are unreachable.

Ports designated as an Initiator on a storage system belonging to the HDS Freedom Storage™

Lightning 9900™ Series or Freedom Storage Lightning 9900V Series cannot be used for

provisioning. If you select one of these ports, you receive a message saying that provisioning

failed because the HiCommand Database was not refreshed. The management server does not

support provisioning for ports designated as Initiators on these storage systems.

The HBAs displayed may not have a connection to the selected storage system. This provides

flexibility. You can select a disconnected HBA for a job to take place when it will be connected

to the storage system.

Keep in mind the following for McDATA and Connectrix switches:

When McDATA or Connectrix switches are discovered through a proxy by using SNMP, you

cannot view or perform any provisioning operations for those switches. For example, you

cannot view zone sets, zones, and/or zone alias.

When McDATA or Connectrix switches are discovered by their IP address by using SNMP, you

can only view the active zone set and its members. You cannot create, modify, and/or delete

zone sets or its members.

Zone aliases are not supported for McDATA or Connectrix switches.