Rev. 1.00, 05/04, page 427 of 544

AV

CC

*

1

AN0 to AN5

AV

SS

Notes: Values are reference values.

2. Rin: Input impedance

1.

*

1

Rin*

2

100

0.1 µF

0.01 µF

10 µF

AV

ref

Figure 16.8 Example of Analog Input Protection Circuit

20 pF

To A/D converter

AN0 to AN5

10 k

Note: * Values are reference values.

Figure 16.9 Equivalent Circuit of Analog Input Pin

16.7.6 Module

Stop Mode Setting

A/D converter operation can be enabled or disabled using the module stop control register. The
initial setting is for A/D converter operation to be halted. Register access is enabled by canceling
module stop mode. For details, refer to section 20, Power-Down Modes.