2 multiprocessor serial data reception – Renesas H8S/2111B User Manual

Page 295

background image

Rev. 1.00, 05/04, page 261 of 544

12.5.2 Multiprocessor

Serial Data Reception

Figure 12.13 shows a sample flowchart for multiprocessor serial data reception. If the MPIE bit
in SCR is set to 1, data is skipped until data with a 1 multiprocessor bit is sent. On receiving data
with a 1 multiprocessor bit, the receive data is transferred to RDR. An RXI interrupt request is
generated at this time. All other SCI operations are the same as in asynchronous mode. Figure
12.12 shows an example of SCI operation for multiprocessor format reception.

MPIE

RDR
value

0

D0

D1

D7

1

1

0

D0

D1

D7

0

1

1

1

Data (ID1)

Start
bit

MPB

Stop
bit

Start
bit

Data (Data 1)

MPB

Stop
bit

Data (ID2)

Start
bit

Stop
bit

Start
bit

Data (Data 2)

Stop
bit

RXI interrupt
request
(multiprocessor
interrupt)
generated

Idle state
(mark state)

RDRF

RDR data read
and RDRF flag
cleared to 0 in
RXI interrupt
handling routine

If not this station’s ID,
MPIE bit is set to 1
again

RXI interrupt request is
not generated, and RDR
retains its state

ID1

(a) Data does not match station’s ID

MPIE

RDR
value

0

D0

D1

D7

1

1

0

D0

D1

D7

0

1

1

1

MPB

MPB

RXI interrupt
request
(multiprocessor
interrupt)
generated

Idle state
(mark state)

RDRF

RDR data read and
RDRF flag cleared
to 0 in RXI interrupt
handling routine

Matches this station’s ID,
so reception continues, and
data is received in RXI
interrupt service routine

MPIE bit set to 1
again

ID2

(b) Data matches station’s ID

Data 2

ID1

MPIE = 0

MPIE = 0

Figure 12.12 Example of SCI Receive Operation (Example with 8-Bit Data, Multiprocessor

Bit, One Stop Bit)