beautypg.com

Renesas H8S/2111B User Manual

Page 454

background image

Rev. 1.00, 05/04, page 420 of 544

Figure 16.2 shows the operation timing.

1. Scan mode is selected (SCAN = 1), scan group 0 is selected (CH2 = 0), analog input channels

AN0 to AN2 are selected (CH1 = 1, CH0 = 0), and A/D conversion is started (ADST = 1).

2. When A/D conversion of the first channel (AN0) is completed, the result is transferred to

ADDRA. Next, conversion of the second channel (AN1) starts automatically.

3. Conversion proceeds in the same way through the third channel (AN2).

4. When conversion of all the selected channels (AN0 to AN2) is completed, the ADF flag is set

to 1 and conversion of the first channel (AN0) starts again. If the ADIE bit is set to 1 at this
time, an ADI interrupt is requested after A/D conversion ends.

5. Steps 2 to 4 are repeated as long as the ADST bit remains set to 1. When the ADST bit is

cleared to 0, A/D conversion stops. After that, if the ADST bit is set to 1, A/D conversion
starts again from the first channel (AN0).

ADST

ADF

ADDRA

ADDRB

ADDRC

ADDRD

State of channel 0 (AN0)

State of channel 1 (AN1)

State of channel 2 (AN2)

State of channel 3 (AN3)

Set*

1

Clear*

1

Idle

Notes: 1. Vertical arrows ( ) indicate instructions executed by software.

2. Data currently being converted is ignored.

Clear*

1

Idle

Idle

A/D conversion time

Idle

Continuous A/D conversion execution

A/D conversion 1

Idle

Idle

Idle

Idle

Idle

Transfer

*

2

A/D conversion 3

A/D conversion 2

A/D conversion 5

A/D conversion 4

A/D conversion result 1

A/D conversion result 2

A/D conversion result 3

A/D conversion result 4

Figure 16.2 Example of A/D Converter Operation

(Scan Mode, Channels AN0 to AN2 Selected)