Rev. 1.00, 05/04, page 242 of 544
Bit Bit
Name
Initial
Value R/W Description
3 PER 0 R/(W)* Parity
Error
[Setting condition]
• When a parity error is detected during reception
[Clearing condition]
• When 0 is written to PER after reading PER = 1
2 TEND
1 R Transmit
End
[Setting conditions]
• When the TE bit in SCR is 0
• When TDRE = 1 at transmission of the last bit of a
1-byte serial transmit character
[Clearing conditions]
• When 0 is written to TDRE after reading TDRE = 1
1 MPB 0 R Multiprocessor
Bit
MPB stores the multiprocessor bit in the receive frame.
When the RE bit in SCR is cleared to 0 its previous
state is retained.
0 MPBT
0 R/W
Multiprocessor
Bit
Transfer
MPBT stores the multiprocessor bit to be added to the
transmit frame.