Show ethernet cfm fault-notify-generator, Ethernet cfm delay-measure two-way, Table 132 – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual
Page 609

Brocade 6910 Ethernet Access Switch Configuration Guide
559
53-1002581-01
CFM Commands
25
show ethernet cfm fault-notify-generator
This command displays configuration settings for the fault notification generator.
Syntax
show ethernet cfm fault-notify-generator mep mpid
mpid – Maintenance end point identifier. (Range: 1-8191)
Default Setting
None
Command Mode
Privileged Exec
Example
This example shows the fault notification settings configured for one MEP.
Console#show ethernet cfm fault-notify-generator mep 1
MD Name MA Name Highest Defect Lowest Alarm Alarm Time Reset Time
------------ ------------ -------------- ------------- ---------- ----------
voip rd none macRemErrXcon 3sec. 10sec.
Console#
ethernet cfm delay-measure two-way
This command sends periodic delay-measure requests to a specified MEP within a maintenance
association.
Syntax
ethernet cfm delay-measure two-way [src-mep source-mpid] {dest-mep destination-mpid |
mac-address} md domain-name ma ma-name [count transmit-count] [interval interval]
[size packet-size] [timeout timeout]
source-mpid – The identifier of a source MEP that will send the delay-measure message.
(Range: 1-8191)
destination-mpid – The identifier of a remote MEP that is the target of the delay-measure
message. (Range: 1-8191)
TABLE 132
show fault-notify-generator - display description
Field
Description
MD Name
The maintenance domain for this entry.
MA Name
The maintenance association for this entry.
Hihest Defect
The highest defect that will generate a fault alarm. (This is disabled by default.)
Lowest Alarm
The lowest defect that will generate a fault alarm (see the
command).
Alarm Time
The time a defect must exist before a fault alarm is issued (see the
, command).
Reset Time
The time after a fault alarm has been issued, and no defect exists, before another
fault alarm can be issued (see the
command).