Show ethernet cfm ma, Show ethernet cfm maintenance-points local – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual
Page 587

Brocade 6910 Ethernet Access Switch Configuration Guide
537
53-1002581-01
CFM Commands
25
show ethernet cfm ma
This command displays the configured maintenance associations.
Syntax
show ethernet cfm ma [level level]
level – Maintenance level. (Range: 0-7)
Default Setting
None
Command Mode
Privileged Exec
Command Usage
For a description of the values displayed in the CC Interval field, refer to the
command.
Example
This example shows all configured maintenance associations.
Console#show ethernet cfm ma
MD Name MA Index MA Name Primary VID CC Interval MIP Creation
--------------- -------- --------------- ----------- ----------- ------------
steve 1 voip 1 4 Default
Console#
show ethernet cfm maintenance-points local
This command displays the maintenance points configured on this device.
Syntax
show ethernet cfm maintenance-points local
{mep [domain domain-name | interface interface | level level-id] |
mip [domain domain-name | level level-id]}
mep – Displays only local maintenance end points.
mip – Displays only local maintenance intermediate points.
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
interface – Displays CFM status for the specified interface.
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-12)
port-channel channel-id (Range: 1-12)
level-id – Maintenance level for this domain. (Range: 0-7)