136
Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002581-01
Flow Sampling Commands
8
Example
Console(config)#sflow
Console(config)#
sflow destination
This command configures the IP address and UDP port used by the Collector. Use the no form to
restore the default settings.
Syntax
sflow destination {ipv4 ipv4-address | ipv6 ipv6-address} [destination-udp-port]
no sflow destination
ipv4-address - IPv4 address of the sFlow Collector. Valid IPv4 addresses consist of four
decimal numbers, 0 to 255, separated by periods.
ipv6-address - IPv6 address of the sFlow Collector. A full IPv6 address including the
network prefix and host address bits. An IPv6 address consists of 8 colon-separated 16-bit
hexadecimal values. One double colon may be used to indicate the appropriate number of
zeros required to fill the undefined fields.
destination-udp-port - The UDP port on which the Collector is listening for sFlow streams.
(Range: 0-65534)
Default Setting
IP Address: null
UDP Port: 6343
Command Mode
Interface Configuration (Ethernet)
Example
This example configures the Collector’s IP address, and uses the default UDP port.
Console(config)#interface ethernet 1/9
Console(config-if)#sflow destination ipv4 192.168.0.4
Console(config-if)#
sflow max-datagram-size
This command configures the maximum size of the sFlow datagram payload. Use the no form to
restore the default setting.
Syntax
sflow max-datagram-size max-datagram-size
no max-datagram-size
max-datagram-size - The maximum size of the sFlow datagram payload.
(Range: 200-1500 bytes)