Transceiver-threshold temperature – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual
Page 323

Brocade 6910 Ethernet Access Switch Configuration Guide
273
53-1002581-01
Interface Commands
12
transceiver-threshold temperature
This command sends a trap when the transceiver temperature falls outside of the specified
thresholds.
Syntax
transceiver-threshold temperature {high-alarm | high-warning | low-alarm | low-warning}
threshold-value
high-alarm – Sends an alarm message when the high temperature threshold is crossed.
high-warning – Sends a warning message when the high temperature threshold is
crossed.
low-alarm – Sends an alarm message when the low temperature threshold is crossed.
low-warning – Sends a warning message when the low temperature threshold is crossed.
threshold-value – The threshold of the transceiver temperature. (Range: -20000 - 20000
in units of 0.01 Celsius)
Default Setting
None
Command Mode
Interface Configuration (Ethernet)
Command Usage
•
Refer to the Command Usage section under the
command for
more information on configuring transceiver thresholds.
•
Trap messages configured by this command are sent to any management station configured by
the
command.
Example
The following example sets alarm thresholds for the transceiver temperature at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold temperature low-alarm 97
Console(config-if)#transceiver-threshold temperature high-alarm -83
Console#