Show sntp, Clock summer-time (date), Show sntp clock summer-time (date) – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual
Page 146

96
Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002581-01
Time
5
Command Usage
This command specifies time servers from which the switch will poll for time updates when set to
SNTP client mode. The client will poll the time servers in the order specified until a response is
received. It issues time synchronization requests based on the interval set via the
command.
Example
Console(config)#sntp server 10.1.0.19
Console#
Related Commands
sntp client (94)
sntp poll (95)
show sntp (96)
show sntp
This command displays the current time and configuration settings for the SNTP client, and
indicates whether or not the local time has been properly updated.
Command Mode
Normal Exec, Privileged Exec
Command Usage
This command displays the current time, the poll interval used for sending time synchronization
requests, and the current SNTP mode (i.e., unicast).
Example
Console#show sntp
Current Time : Nov 5 18:51:22 2006
Poll Interval : 16 seconds
Current Mode : Unicast
SNTP Status : Enabled
SNTP Server : 137.92.140.80 0.0.0.0 0.0.0.0
Current Server : 137.92.140.80
Console#
clock summer-time (date)
This command sets the start, end, and offset times of summer time (daylight savings time) for the
switch on a one-time basis. Use the no form to disable summer time.
Syntax
clock summer-time name date {[b-day b-month] | [b-month b-day]} b-year b-hour b-minute
{[e-day e-month] | [e-month e-day]} e-year e-hour e-minute [offset]
no clock summer-time
name - Name of the time zone while summer time is in effect, usually an acronym.
(Range: 1-30 characters)
b-day - The day summer time will begin. (Options: 1-31)