Page 102

52
Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002581-01
Banner Information
5
row-id - The row number.
rack-id - The rack number.
sr-id - The shelf number in the rack.
mfr-name - The name of the device manufacturer.
Maximum length of each parameter: 32 characters
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure equipment-info command interprets
spaces as data input boundaries. The use of underscores ( _ ) or other unobtrusive non-letter
characters is suggested for situations where white space is necessary for clarity.
Example
Console(config)#banner configure equipment-info manufacturer-id BR6910 floor 3
row 10 rack 15 shelf-rack 12 manufacturer Brocade
Console(config)#
banner configure equipment-location
This command is used to configure the equipment location information displayed in the banner.
Use the no form to restore the default setting.
Syntax
banner configure equipment-location location
no banner configure equipment-location
location - The address location of the device.
(Maximum length: 32 characters)
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure equipment-location command
interprets spaces as data input boundaries. The use of underscores ( _ ) or other unobtrusive
non-letter characters is suggested for situations where white space is necessary for clarity.