Snmp-server enable traps ethernet cfm cc, Mep archive-hold-time – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual
Page 594

544
Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002581-01
CFM Commands
25
snmp-server enable traps ethernet cfm cc
This command enables SNMP traps for CFM continuity check events. Use the no form to disable
these traps.
Syntax
[no] snmp-server enable traps ethernet cfm cc [config | loop | mep-down | mep-up]
config – Sends a trap if this device receives a CCM with the same MPID as its own but with
a different source MAC address, indicating that a CFM configuration error exists.
loop – Sends a trap if this device receives a CCM with the same source MAC address and
MPID as its own, indicating that a forwarding loop exists.
mep-down – Sends a trap if this device loses connectivity with a remote MEP, or
connectivity has been restored to a remote MEP which has recovered from an error
condition.
mep-up – Sends a trap if a remote MEP is discovered and added to the local database, the
port state of a previously discovered remote MEP changes, or a CCM is received from a
remote MEP which as an expired entry in the archived database.
Default Setting
All continuity checks are enabled.
Command Mode
Global Configuration
Command Usage
All mep-up traps are suppressed when cross-checking of MEPs is enabled because cross-check
traps include more detailed status information.
Example
This example enables SNMP traps for mep-up events.
Console(config)#snmp-server enable traps ethernet cfm cc mep-up
Console(config)#
Related Commands
ethernet cfm mep crosscheck (549)
mep archive-hold-time
This command sets the time that data from a missing MEP is retained in the continuity check
message (CCM) database before being purged. Use the no form to restore the default setting.
Syntax
mep archive-hold-time hold-time
hold-time – The time to retain data for a missing MEP. (Range: 1-65535 minutes)