Show logging sendmail, Time, Table 23 – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual
Page 143: Show logging sendmail (93)

Brocade 6910 Ethernet Access Switch Configuration Guide
93
53-1002581-01
Time
5
Default Setting
None
Command Mode
Global Configuration
Command Usage
You may use an symbolic email address that identifies the switch, or the address of an
administrator responsible for the switch.
Example
Console(config)#logging sendmail source-email [email protected]
Console(config)#
show logging sendmail
This command displays the settings for the SMTP event handler.
Command Mode
Normal Exec, Privileged Exec
Example
Console#show logging sendmail
SMTP servers
-----------------------------------------------
192.168.1.19
SMTP Minimum Severity Level: 7
SMTP destination email addresses
-----------------------------------------------
SMTP Source Email Address: [email protected]
SMTP Status: Enabled
Console#
Time
The system clock can be dynamically set by polling a set of specified time servers (NTP or SNTP).
Maintaining an accurate time on the switch enables the system log to record meaningful dates and
times for event entries. If the clock is not set, the switch will only record the time from the factory
default set at the last bootup.
TABLE 23
Time Commands
Command
Function
Mode
SNTP Commands
Accepts time from specified time servers
GC
Sets the interval at which the client polls for time
GC