Sntrapchassisfanspeedhi gh, Fdrytraplagdeployed, Fdrytraplagundeployed – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 752: Sntrapfipsmodeenable, Sntrapfipsmodedisable, Sntrapfipshostzeroized, Sntrapfipssharedsecretz eroized, Sntrapfipspoststatus, Sntrapfipscryptomodulef ailure, Sntraplicense2portnotsu pported

724
Unified IP MIB Reference
53-1002549-02
General traps for the Brocade NetIron devices
snTrapChassisFanSpeedHi
gh
brcdIp.0.1203
snAgGblTrapMessage
Informational The speed of all the chassis fans changed to
high.
Sample trap message:
System: Set fan speed to HI
(100%%)
fdryTrapLagDeployed
brcdIp.0.1204
fdryLAGName,
fdryLinkAggregationG
roupIfIndex
Informational The SNMP trap is generated when a LAG is
deployed.
fdryTrapLagUndeployed
brcdIp.0.1205
fdryLAGName,
fdryLinkAggregationG
roupIfIndex
Informational The SNMP trap is generated when a LAG is
undeployed.
snTrapFIPSModeEnable
brcdIp.0.1207
snAgGblTrapMessage
Informational The SNMP trap is generated when Federal
Information Processing Standard (FIPS)
mode is enabled.
snTrapFIPSModeDisable
brcdIp.0.1208
snAgGblTrapMessage
Informational The SNMP trap is generated when FIPS
mode is disabled.
snTrapFIPSHostZeroized
brcdIp.0.1209
snAgGblTrapMessage
Informational The SNMP trap is generated when host keys
are set to zero(0) in FIPS mode.
snTrapFIPSSharedSecretZ
eroized
brcdIp.0.1210
snAgGblTrapMessage
Informational The SNMP trap is generated when shared
secrets are set to zero(0) in FIPS mode.
snTrapFIPSPOSTStatus
brcdIp.0.1211
snAgGblTrapMessage
Informational The SNMP trap is generated after POST.
snTrapFIPSCryptoModuleF
ailure
brcdIp.0.1212
snAgGblTrapMessage
Critical
The SNMP trap is generated when the
cryptographic module fails.
snTrapLicense2PortNotSu
pported
brcdIp.0.1213
snAgGblTrapMessage
Notifications
The SNMP trap is generated when at
two-port licenses cannot be applied due to
hardware limitation.
snTrapOpticalMonitoringO
K
brcdIp.0.1214
snAgGblTrapMessag,
ifIndex
Informational The SNMP trap is generated when an
interface transitions from an error state to
the normal state because the alarms or
warnings are below the threshold value. The
snTrapOpticalMonitoringError is generated
when the interface transitioned to the error
state.
The first varbind snAgGblTrapMessage, will
have a detailed message on the cause of
event. The second varbind ifIndex, points to
the affected interface that originates the
event. If an event does not have associated
port or has multiple associated ports, then
ifIndex has the maximum value 0x7ffffff.
snTrapSFMAccessOK
brcdIp.0.1215
snAgGblTrapMessage
Informational The SNMP trap is generated when system
can successfully access an SFM Fabric
Element (FE).
The snTrapSFMAccessError is generated
when the system failed to access the FE.
Trap name and number
Varbinds
Severity
Description and trap message