Snchassystemmode, Snchasfactorypartnumber, Snchasfactoryserialnumbe r – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 155: Power supply table, Snchaspwrsupplytable, Snchaspwrsupplyindex, Snchaspwrsupplydescription, Snchaspwrsupplyoperstatus

Unified IP MIB Reference
127
53-1002549-02
Power supply table
Power supply table
The following table applies to the power supply in all products.
snChasSystemMode
brcdIp.1.1.1.1.27
Syntax: Integer
NOTE: This object is not
supported on the
Brocade FastIron
devices.
Read-only
This object displays the mode of the Brocade MLXe router, Brocade
NetIron XMR, or Brocade NetIron MLX device. It returns one of the
following values:
•
xmr(1)
•
mlx(2)
Values are returned as follows:
•
If snChasProductType is niXmr4000, niXmr8000, niXmr160000,
or niXmr32000, then this object returns xmr(1).
•
if snChasProductType is niMlx4, niMlx8, niMlx16, or niMlx32 then
this object returns mlx(2).
•
If snChasProductType is brMlxE4, brMlxE8, brMlxE16, or
brMlxE32 this object returns either xmr(1) or mlx(2) depending
on the mode of the system.
snChasFactoryPartNumber
brcdIp.1.1.1.1.28
Syntax: DisplayString
NOTE: This object is not
supported on the
Brocade FastIron
devices.
Read-only
This object displays the factory part number assigned by the
manufacturer.
snChasFactorySerialNumbe
r
brcdIp.1.1.1.1.29
Syntax: DisplayString
NOTE: This object is not
supported on the
Brocade FastIron
devices.
Read-only
This object displays the factory serial number assigned by the
manufacturer.
Name, OID, and syntax
Access
Description
Name, OID, and syntax
Access
Description
snChasPwrSupplyTable
brcdIp.1.1.1.2.1
None
A table containing power supply information. Only installed power
supplies appear in the table.
snChasPwrSupplyIndex
brcdIp.1.1.1.2.1.1.1
Syntax: Integer32
Read-only The index to the power supply table.
snChasPwrSupplyDescription
brcdIp.1.1.1.2.1.1.2
Syntax: DisplayString
Read-only The power supply description. For example, you may see the
description, “right side power supply”. This object can have up to 128
characters.
snChasPwrSupplyOperStatus
brcdIp.1.1.1.2.1.1.3
Syntax: Integer
Read-only The status of the power supply:
•
other(1) – Status is neither normal(2) or failure(3). This value is
not used for stackables including FastIron 4802.
•
normal(2)
•
failure(3)