beautypg.com

Igmpcacheaddress, Igmpcacheifindex, Igmpcacheself – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual

Page 57: Igmpcachelastreporter, Igmpcacheuptime, Igmpcacheexpirytime, Igmpcachestatus, Igmpcacheversion1hosttimer, Support on fastiron devices, Pimjoinpruneinterval

background image

Unified IP MIB Reference

29

53-1002549-02

RFC 2934: Protocol Independent Multicast MIB for IPv4

RFC 2934: Protocol Independent Multicast MIB for IPv4

Support on FastIron devices

FastIron devices support the following objects from RFC 2934. FastIron devices do not support PIM
Border.

pimInterfaceTable (PIM interface table)

Object

Object identifier

Supported?

igmpCacheAddress

1.3.6.1.2.1.85.1.2.1.1

Yes

igmpCacheIfIndex 1.3.6.1.2.1.85.1.2.1.2

Yes

igmpCacheSelf

1.3.6.1.2.1.85.1.2.1.3

Yes, but read-only.

igmpCacheLastReporter 1.3.6.1.2.1.85.1.2.1.4

Yes, but read-only.
NOTE: On Brocade NetIron MLX

,

Brocade MLXe

,

Brocade

NetIron XMR

,

Brocade

NetIron CES, and Brocade
NetIron CER series

devices,

the constant value for this
object is 0.

igmpCacheUpTime

1.3.6.1.2.1.85.1.2.1.5

Yes, but read-only.

igmpCacheExpiryTime 1.3.6.1.2.1.85.1.2.1.6

Yes, but read-only.

igmpCacheStatus

1.3.6.1.2.1.85.1.2.1.7

Yes, but read-only.
NOTE: On Brocade NetIron MLX

,

Brocade MLXe

,

Brocade

NetIron XMR

,

Brocade

NetIron CES, and Brocade
NetIron CER series

devices,

the constant value for this
object is active(1).

igmpCacheVersion1HostTimer

1.3.6.1.2.1.85.1.2.1.8

Yes, but read-only.

Object

Object identifier

pimJoinPruneInterval 1.3.6.1.3.61.1.1.1

Object

Object identifier

pimInterfaceIfIndex 1.3.6.1.3.61.1.1.2.1.1

pimInterfaceAddress 1.3.6.1.3.61.1.1.2.1.2

pimInterfaceNetMask

1.3.6.1.3.61.1.1.2.1.3

pimInterfaceMode 1.3.6.1.3.61.1.1.2.1.4

pimInterfaceDR 1.3.6.1.3.61.1.1.2.1.5