Packet over sonet traps, Sntrapposmonitoringwarning, Sntrapposmonitoringalarm – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 719: Sntrapposmonitoringerror, Mac-based vlan traps, Sntrapmacauthvlanidchang e, Sntrapmacbasedvlanenable d, Sntrapmacbasedvlandisabl ed

Unified IP MIB Reference
691
53-1002549-02
Proprietary traps
Packet over SONET traps
The following contains packet over SONET traps that are supported only on the Brocade NetIron
MLX, Brocade MLXe, Brocade NetIron XMR, Brocade NetIron CES, and Brocade NetIron CER series
devices.
MAC-based VLAN traps
The following table contains MAC-based VLAN traps that are supported only on the FastIron
devices.
Trap name and number
Varbinds
Severity
Description
snTrapPosMonitoringWarning
brcdIp.0.1006
snAgGblTrapMes
sage
Informational A warning occurred during POS alarm
monitoring.
snTrapPosMonitoringAlarm
brcdIp.0.1007
snAgGblTrapMes
sage
Alert
An alarm up or alarm down incident occurred
during POS alarm monitoring.
snTrapPosMonitoringError
brcdIp.0.1008
snAgGblTrapMes
sage
Informational An error occurred during POS alarm
monitoring.
Trap name and number
Varbinds
Severity
Description and trap message
snTrapMacAuthVlanIdChang
e
brcdIp.0.138
snAgGblTrapMessage Notifica
tion
VLAN ID of a port has changed.
snTrapMacBasedVlanEnable
d
brcdIp.0.147
snAgGblTrapMessage
Notifica
tion
MAC-based VLAN is enabled.
Sample trap message:
SNTrapMacBasedVlanEnabled: Mac
Based Vlan Enabled on port id>. snTrapMacBasedVlanDisabl snAgGblTrapMessage Notifica MAC-based VLAN is disabled. Based Vlan Disabled on port id>.
ed
brcdIp.0.148
tion
Sample trap message:
SNTrapMacBasedVlanDisabled: Mac