Sntrapl2caccesslog, Sntrapdot1agcfmremote mepup, Sntrapdot1agcfmdomain crossconnection – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 749: Sntrapdot1agcfmduplicat emepid, Sntrapchasfanok

Unified IP MIB Reference
721
53-1002549-02
General traps for the Brocade NetIron devices
snTrapl2CAccessLog
brcdIp.0.184
snAgGblTrapMessage
Notification
This trap is generated to provide information
about the state of the I2C access of the
management module.
Sample trap message:
last good i2c access, Mux index
0, Mux tap 0, ID 0x9, Addr 0x1,
(SNM2TEMP)
bad i2c access (GIEI = set),
Severity Minor, Mux index 0,
Mux tap2, ID 0x9, Addr 0x1,
(SNM3TEMP)
snTrapDot1agCfmRemote
MEPAgeOut
brcdIp.0.192
dot1agCfmMdName,
dot1agCfmMaNetNa
me,
dot1agCfmMepDbRM
epState,
snAgGblTrapMessage
Warning
This trap is generated when the 802.1ag
Remote MEP ages out.
Sample trap message:
System: Remote MEP 2 in Domain
maint_domain, MA maint_asso
aged out
snTrapDot1agCfmRemote
MEPUp
brcdIp.0.193
dot1agCfmMdName,
dot1agCfmMaNetNa
me,
dot1agCfmMepDbRM
epState,
snAgGblTrapMessage
Informational This trap is generated when the 802.1ag
Remote MEP is up.
Sample trap message:
System: Remote MEP 2 in Domain
maint_domain, MA maint_asso
become UP state
snTrapDot1agCfmDomain
CrossConnection
brcdIp.0.194.
dot1agCfmMdName,
dot1agCfmMaNetNa
me,
snAgGblTrapMessage
Warning
This trap is generated when the 802.1ag
domain gets cross-connected.
Sample trap message:
System: Cross Connection in
Domain MLX4maintDomain, MA
MLX4maintAsso
snTrapDot1agCfmDuplicat
eMEPId
brcdIp.0.195
dot1agCfmMdName,
dot1agCfmMaNetNa
me,
dot1agCfmMepDbRM
epState,
snAgGblTrapMessage
Warning
This trap is generated when the 802.1ag
Remote MEP reports a duplicate MEP ID
that conflicts with a local MEP ID.
Sample trap message:
System: Remote MEP ID 1 in
Domain MLX4maintDomain, MA
MLX4maintAsso is same as ours
snTrapChasFanOK
brcdIp.0.1000
snChasFanIndex,
snChasFanDescriptio
n
Minor
One of the following occurred on the device:
•
The status of the fan operation
changed from failure to normal.
•
Fan speed changed due to a decrease
in the operating temperature.
Sample trap message:
Right fan tray (fan1) OK
Trap name and number
Varbinds
Severity
Description and trap message