Snchasmedialeds, Snchasenablepwrsupplytr ap, Snchasmainbrdid – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 150

122
Unified IP MIB Reference
53-1002549-02
Fan status
snChasMediaLeds
brcdIp.1.1.1.1.11
Syntax: Integer
NOTE: This object is not
supported on the
Brocade MLXe,
Brocade NetIron
MLX, Brocade
NetIron XMR,
Brocade NetIron
CES, and Brocade
NetIron CER series
devices.
Read-only
This object is replaced by the object snAgentBrdMediaLedString.
It is represented by one bit. There can be up to 32 bits per slot. Status
can be one of the following:
•
0 – Half-duplex
•
1 – Full-duplex
snChasEnablePwrSupplyTr
ap
brcdIp.1.1.1.1.12
Syntax: Integer
Read-write Indicates if the SNMP agent process has been enabled to generate
power supply failure traps:
•
disabled(0)
•
enabled(1)
Default: enabled(1)
snChasMainBrdId
brcdIp.1.1.1.1.13
Syntax: OCTET STRING
NOTE: This object is not
supported on the
Brocade MLXe
router, Brocade
NetIron XMR,
Brocade NetIron
MLX, Brocade
NetIron CES,
Brocade NetIron
CER series and on
the FastIron
devices.
Read-only
Applies to all stackable products. It identifies the main board. This is
an encoded octet string. Each octet provides the following information:
Octet 0 – Identifies the format of this octet string.
Octets 1 and 2:
If Octet 0 has a value of 1, then:
Octet 1 – Product type:
•
FIWG – 0x57
•
FIBB – 0x42
•
FIMLS – 0x4D
•
NI – 0x4E
•
TI – 0x54
•
TIRT – 0x52
Octet 2 – Board type:
•
POWERPC – 1
•
ALPHA – 2
The length of the octet string is 27.
If Octet 0 has a value of 2, then:
Octet 1 – Product type:
•
BI_WG – 0x57
•
BI_BB – 0x42
•
BI_NI – 0x4E
•
NI_M4 – 0x4D
•
BI_SLB – 0x53
Octet 2 – Module type:
•
MASTER_FIBER_8G – 0x0
•
MASTER_FIBER_4G – 0x1
•
MASTER_COPPER_16 – 0x2
•
FI_MASTER_FIBER_2G – 0x4
•
FI_MASTER_FIBER_4G – 0x5
•
MASTER_COPPER_8G – 0x6
•
FI_MASTER_FIBER_8G – 0x7
Name, OID, and syntax
Access
Description