Sntp mib definition, Ntp general group, Snntpgeneral – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 261: Snntppollinterval, Snntptimezone, Chapter 12, Chapter

Unified IP MIB Reference
233
53-1002549-02
Chapter
12
SNTP MIB Definition
In this chapter
•
•
•
SNTP server table (FastIron X series IPv6 devices). . . . . . . . . . . . . . . . . . . 236
NTP general group
You can configure Layer 2 and Layer 3 switches to consult SNTP servers for the current system time
and date. As Layer 2 and Layer 3 switches do not retain time and date information across power
cycles, using the SNTP feature alleviates the need to reconfigure time and date after a system
reset.
The following objects provide information on the NTP server. These objects apply to all devices.
Name, OID, and syntax
Access
Description
snNTPGeneral
brcdIp.1.1.3.11.1
None
Begins the NTP configuration objects.
snNTPPollInterval
brcdIp.1.1.3.11.1.1
Syntax: Integer
NOTE: This MIB object is
deprectated on the
Brocade NetIron
devices.
Read-write
Specifies how often to poll the NTP server. Each unit is one second.
Valid values: 1 – 65535
Default: 1800 seconds
snNTPTimeZone
brcdIp.1.1.3.11.1.2
Syntax: Integer
Read-write
Time zone:
•
alaska(0)
•
aleutian(1)
•
arizona(2)
•
central(3)
•
eastIndiana(4)
•
eastern(5)
•
hawaii(6)
•
michigan(7)
•
mountain(8)
•
pacific(9)
•
samoa(10)
•
gmtPlus1200(11)
•
gmtPlus1100(12)
•
gmtPlus1000(13)
•
gmtPlus0900(14)