Sntrapportsecurityviolation, Sntrapportsecurityshutdown, Mrp traps – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 734: Sntrapmrpstatechange, Sntrapmrpcamerror, Mpls notifications, Fdryvplscreated
706
Unified IP MIB Reference
53-1002549-02
Proprietary traps
MRP traps
The following traps are generated for MRP functionalities.
MPLS notifications
NOTE
The following MPLS traps are included in the Unified IP MIB but they are not supported:
snTrapMplsProblem (brcdIp.0.57)
snTrapMplsException (brcdIp.0.58)
snTrapMplsAudit (brcdIp.0.59)
snTrapMplsDeveloper (brcdIp.0.60)
The following traps are supported only on the Brocade NetIron MLX, Brocade MLXe, Brocade
NetIron XMR, Brocade NetIron CES, and Brocade NetIron CER series devices.
Trap name and number
Varbinds
Severity
Description and trap message
snTrapPortSecurityViolation
brcdIp.0.77
snAgGblTrapMessage Minor
Packets from an unknown MAC address
are dropped.
Sample trap message:
Brocade Trap: Port Security
Violation
snTrapPortSecurityShutdown
brcdIp.0.78
snAgGblTrapMessage Minor
The port is disabled for the amount of
time configured using the violation
shutdown
command.
Sample trap message:
Brocade Trap: Port Security
Violation Cause Shutdown
Trap name and number
Varbinds
Severity
Description
snTrapMrpStateChange
brcdIp.0.79
snAgGblTrapMessage
Informational An MRP state occurred.
snTrapMrpCamError
brcdIp.0.80
snAgGblTrapMessage
Warning
An MRP CAM error occurred.
Trap name and number
Varbinds
Severity
Description
fdryVplsCreated
brcdIp.1.2.15.2.0.1
vplsConfigName
fdryVplsVcId
Informational
Generated when an entry is created in the
fdryVplsTable.
It is not generated during system bootup time.