Snchasunitactualtemp erature, Snchasunitwarningtem perature, Snchasunitshutdownte mperature – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 158: Snchasunitpartnum

130
Unified IP MIB Reference
53-1002549-02
Stacking chassis unit information
snChasUnitActualTemp
erature
brcdIp.1.1.1.4.1.1.4
Syntax: Integer
NOTE: This object is
not supported
on the Brocade
MLXe, Brocade
NetIron MLX,
Brocade NetIron
XMR, Brocade
NetIron CES,
and Brocade
NetIron CER
series devices.
Read-only
Temperature of the chassis. Each unit is 0.5º Celsius. This object
applies only to management modules with temperature sensors in
hardware. For management modules without temperature sensors, it
returns “no-such-name”.
Values are from -110 through 250º Celsius.
snChasUnitWarningTem
perature
brcdIp.1.1.1.4.1.1.5
Syntax: Integer
NOTE: This object is
not supported
on the Brocade
MLXe, Brocade
NetIron MLX,
Brocade NetIron
XMR, Brocade
NetIron CES,
and Brocade
NetIron CER
series devices.
Read-only
Actual temperature higher than the threshold value triggers the switch
to send a temperature warning trap. Each unit is 0.5º Celsius.
This object applies only to management modules with temperature
sensors in hardware. For management modules without temperature
sensors, it returns “no-such-name”.
Values are from 0 through 250º Celsius.
snChasUnitShutdownTe
mperature
brcdIp.1.1.1.4.1.1.6
Syntax: Integer
NOTE: This object is
not supported
on the Brocade
MLXe, Brocade
NetIron MLX,
Brocade NetIron
XMR, Brocade
NetIron CES,
and Brocade
NetIron CER
series devices.
Read-only
Actual temperature higher than the threshold value will shut down a
portion of the switch hardware to cool down the system. Each unit is
0.5º Celsius. This object applies only to management modules with
temperature sensors in hardware. For management modules without
temperature sensors, it returns “no-such-name”.
Values are from 0 through 250º Celsius.
snChasUnitPartNum
brcdIp. 1.1.1.4.1.1.7
Syntax: DisplayString
Read-only
Indicates the part number of the chassis only for Brocade NetIron
XMR, Brocade NetIron MLX, Brocade MLXe router devices. Nothing is
displayed if the part number is unknown or unavailable.
Name, OID, and syntax
Access
Description