Snagentbrd2mainporttot al, Snagentbrd2modulestat us, Snagentbrd2redundants tatus – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 185: Trap receiver table

Unified IP MIB Reference
157
53-1002549-02
Trap receiver table
Trap receiver table
The trap receiver table allows you to configure trap receivers on IPv4 devices.
NOTE
To delete a trap receiver, the agent needs the following varbinds in the setRequest PDU:
snAgTrpRcvrIpAddr, snAgTrpRcvrCommunityOrSecurityName, and snAgTrpRcvrStatus. The
snAgTrpRcvrStatus object must be set to delete(3).
snAgentBrd2MainBrdId
(continued)
•
LX_SX_FIBER=4
•
LHB_FIBER=5
Octet 10 to Octet 13 – Size of DRAM in Kilobytes.
Octet 14 to Octet 17 – Size of boot flash in Kilobytes.
Octet 18 to Octet 21 – Size of code flash in Kilobytes.
Octet 22 to Octet 27 – Serial number.
Octet 28 – Chassis backplane type:
•
chassis4000 – 0x00
•
chassis8000 – 0x02
•
chassis15000 – 0x01
•
chassisFISX – 0x04
•
Turbo8 – 0x07 (stack2)
•
FastIron2 – 0x06 (stack1)
snAgentBrd2MainPortTot
al
brcdIp.1.1.2.2.2.1.5
Syntax: Integer
Read-only
The total number of ports for the main board.
snAgentBrd2ModuleStat
us
brcdIp.1.1.2.2.2.1.6
Syntax: Integer
Read-only
Shows the status of the module. The following are the status of the
module:
•
moduleEmpty(0) – The slot of the chassis is empty.
•
moduleGoingDown(2) – The module is going down.
•
moduleRejected(3) – The module is being rejected due to wrong
configuration.
•
moduleBad(4) – The module hardware is bad.
•
moduleConfigured(8) – The module is configured (stacking).
•
moduleComingUp(9) – The module is in power-up cycle.
•
moduleRunning(10) – The module is running.
•
moduleBlocked(11) – The module is blocked for full height card.
By default, this mode is set to notActivated(0).
snAgentBrd2RedundantS
tatus
brcdIp.1.1.2.2.2.1.7
Syntax: Integer
Read-only
The status of a redundant module. Non-management modules always
return other(1). Management modules return the other states:
•
other(1)
•
active(2)
•
standby(3)
•
crashed(4)
•
comingUp(5)
Name, OID, and syntax
Access
Description