Switch port information
snSwIfInfoPortQos
brcdIp.1.1.3.3.5.1.12
Syntax: Integer
Read-write
Indicates the Quality of Service (QoS) level selected for the port:
•
low(0) – Low priority
•
high(1) – High priority
•
level0(0)
•
level1(1)
•
level2(2)
•
level3(3)
•
level4(4)
•
level5(5)
•
level6(6)
•
level7(7)
snSwIfInfoPhysAddress
brcdIp.1.1.3.3.5.1.13
Syntax: Physical address
Read-only
Shows the physical address of the port.
snSwIfLockAddressCount
brcdIp.1.1.3.3.5.1.14
Syntax: Integer
Read-write
Indicates the number of source MAC addresses that are allowed on the
interface.
Valid values: 0 – 2048. The value 0 means an unlimited number of
addresses are allowed.
Default: 8
snSwIfStpPortEnable
brcdIp.1.1.3.3.5.1.15
Syntax: Integer
Read-write
Indicates if STP is enabled for the port:
•
disabled(0)
•
enabled(1)
snSwIfDhcpGateListId
brcdIp.1.1.3.3.5.1.16
Syntax: Integer
Read-write
Specifies the ID for a DHCP gateway list entry relative to this switch port.
Valid values: 0 – 32. A value of 0 means that the ID is unassigned.
snSwIfName
brcdIp.1.1.3.3.5.1.17
Syntax: Display string
Read-write
Indicates the port name or description. This description may have been
entered using the CLI.
Valid values: Up to 32 characters for most devices. Up to 255 characters
for Brocade MLXe router devices and other Brocade NetIron devices.
snSwIfDescr
brcdIp.1.1.3.3.5.1.18
Syntax: Display string
Read-only
A textual string containing the slot or port information about the
interface.
snSwIfInfoAutoNegotiate
brcdIp.1.1.3.3.5.1.19
Syntax: Integer
Read-write
Applies only to Gigabit Ethernet ports.
Indicates if auto-negotiation mode is enabled on the port:
•
disabled(0) – The port will be placed in non-negotiation mode.
•
enabled(1) – The port will start auto-negotiation indefinitely until it
succeeds.
•
negFullAuto(2) – The port will start with auto-negotiation. If the
negotiation fails, then it will automatically switch to non-negotiation
mode. This option is not supported in stackable products with
Gigabit Ethernet ports, except for TurboIron/8.
•
global(3) – The port negotiation mode follows the value of
snSwGlobalAutoNegotiate.
•
other(4) – Non-Gigabit Ethernet port returns this value.
Default: global(3)
snSwIfInfoFlowControl
brcdIp.1.1.3.3.5.1.20
Syntax: Integer
Read-write
Indicates if port flow control is enabled:
•
disable(0)
•
enable(1)
Default: enabled(1)