Sntrapstackingmasterelecte d, Sntrapstackingunitadded, Sntrapstackingunitdeleted – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 745: Sntrapstackingchaspwrsup plyok, Sntrapstackingchaspwrsup plyfailed, Sntrapstackingchasfannor mal, Sntrapstackingchasfanfaile d, Sntrapstackingmanagement macchanged

Unified IP MIB Reference
717
53-1002549-02
Proprietary traps
Trap name and number
Varbinds
Severity Description and trap message
snTrapStackingMasterElecte
d
brcdIp.0.163
snChasUnitIndex,
snAgGblTrapMessage
Minor
The SNMP trap that is generated when a unit is
elected as the Master unit for the stacking
system.
Sample trap message:
Stack unit
elected as ACTIVE unit of the
stack system
snTrapStackingUnitAdded
brcdIp.0.164
snChasUnitIndex,
snAgGblTrapMessage
Minor
The SNMP trap that is generated when a unit
has been added to the stacking system.
Sample trap message:
Stack: Stack unit
has been added to the stack system
snTrapStackingUnitDeleted
brcdIp.0.165
snChasUnitIndex,
snAgGblTrapMessage
Minor
The SNMP trap that is generated when a unit
has been deleted from the stacking system.
Sample trap message:
Stack: Stack unit
has been deleted to the stack
system
snTrapStackingChasPwrSup
plyOK
brcdIp.0.166
snChasUnitIndex,
snChasPwrSupplyInde
x,
snAgGblTrapMessage
Minor
The SNMP trap that is generated when a power
supply operational status changed from failure
to normal for a stacking system.
Sample trap message:
System: Stack unit
Power supply
snTrapStackingChasPwrSup
plyFailed
brcdIp.0.167
snChasUnitIndex,
snChasPwrSupplyInde
x,
snAgGblTrapMessage
Minor
The SNMP trap that is generated when a power
supply operational status changed from normal
to failure for a stacking system.
Sample trap message:
System: Stack unit
Power supply
snTrapStackingChasFanNor
mal
brcdIp.0.168
snChasUnitIndex,
snChasFanIndex,
snChasFanDescriptio
n
Minor
The SNMP trap that is generated when a fan
operational status changed from failure to
normal for a stacking system.
Sample trap message:
System: Stack unit
Fan
(
snTrapStackingChasFanFaile
d
brcdIp.0.169
snChasUnitIndex,
snChasFanIndex,
snChasFanDescriptio
n
Minor
The SNMP trap that is generated when a fan
fails to operate normally for a stacking system.
Sample trap message:
System: Stack unit
Fan
(
snTrapStackingManagement
MACChanged
brcdIp.0.170
snAgGblTrapMessage Minor
The SNMP trap that is generated when the
managemnet MAC address of a stacking
system has been changed.
Sample trap message:
System: Management MAC address
changed to