IP RIP general group
snRtIpRipRedisEnable
brcdIp.1.2.3.1.3
Syntax: Integer
NOTE: This object is not
supported on the
Brocade MLXe router,
Brocade NetIron XMR,
Brocade NetIron MLX,
Brocade NetIron CES,
and Brocade NetIron
CER series devices.
Read-write
Indicates if redistribution of static routes from the IP route table
into RIP is enabled:
•
disabled(0)
•
enabled(1)
Default: disabled(0)
snRtIpRipRedisDefMetric
brcdIp.1.2.3.1.4
Syntax: Integer
Read-write
Shows the default metric to be used when static routes are
redistributed to RIP.
Valid values: 1 – 15
snRtIpRipSetAllPortConfig
brcdIp.1.2.3.1.5
Syntax: Integer32
NOTE: This object is not
supported on the
Brocade MLXe router,
Brocade NetIron XMR,
Brocade NetIron MLX,
Brocade NetIron CES,
and Brocade NetIron
CER series devices.
Read-write
The value of this object is a number corresponding to a row in the
“snRtIpRipPortConfigPortIndex”
object of
. The values of the
objects
will be written to that row.
NOTE: Before setting this object, all the intended data of the given
row of the table must be set. Otherwise, the current data of
the row will be used to set the entire
. The previous setting will be
overwritten by the new one.
snRtIpRipGblFiltList
brcdIp.1.2.3.1.6
Syntax: OCTET STRING
NOTE: This object is not
supported on the
Brocade MLXe router,
Brocade NetIron XMR,
Brocade NetIron MLX,
Brocade NetIron CES,
and Brocade NetIron
CER series devices.
Read-write
An IP RIP global filter list. Each octet contains a filter ID number
that forms a group of filters. A valid entry in
with the corresponding filter ID
number in the
object must be created
before a filter list is initialized.
Valid values: 1 – 64 octets
snRtIpRipFiltOnAllPort
brcdIp.1.2.3.1.7
Syntax: Integer
NOTE: This object is not
supported on the
Brocade NetIron MLX,
Brocade MLXe router,
Brocade NetIron XMR,
Brocade NetIron CES,
and Brocade NetIron
CER series devices.
Read-write
Applies the IP RIP global filter object
to all
interfaces. This object is used to add and delete all RIP filter lists to
and from all interfaces. Prior to sending this command,
must contain the correct filter list.
The following values can be written:
•
deleteAllInBound(2) – Delete all in-bound filter lists from all
ports.
•
deleteAllOutBound(3) – Delete all out-bound filter lists from all
ports.
•
addAllInBound(4) – Add all in-bound filter lists to all ports.
•
addAllOutBound(5) – Add all out-bound filter lists to all ports.
If a set operation failed, then a SET with value of (2) or (3) returns
the error code "GenError". If the operation succeeded, then entries
in this filter list are deleted immediately.
The following value is returned on reads:
•
valid(1) – Set operation is done and is valid.
Name, OID, and syntax
Access
Description