Sntrapopticalmonitoringwarn ing, Sntrapopticalmonitoringalar m, Sntrapopticalmonitoringerror – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 743

Unified IP MIB Reference
715
53-1002549-02
Proprietary traps
Trap name and number
Varbinds
Severity
Description and trap message
snTrapOpticalMonitoringWarn
ing
brcdIp.0.1003
NOTE: This trap is also
supported on the
FastIron devices.
snAgGblTrapMessage
Warning
A warning occurred during optical
monitoring.
Sample trap message:
Latched high Temperature
alarm, port
snTrapOpticalMonitoringAlar
m
brcdIp.0.1004
NOTE: This trap is also
supported on the
FastIron devices.
snAgGblTrapMessage
Alerts
An alarm occurred during optical
monitoring due to a low temperature in the
device.
Sample trap message:
Latched low Temperature alarm,
port
snTrapOpticalMonitoringError
brcdIp.0.1005
NOTE: This trap is also
supported on the
FastIron devices.
snAgGblTrapMessage
Informati
onal
An error occurred during optical
monitoring.
Samples trap message:
OPTICAL MONITORING:
sys_create_timer failed, slot
OPTICAL MONITORING:
sys_set_timer failed, slot
OPTICAL MONITORING: THRESHOLDS
READ FAILED, port
OPTICAL MONITORING: AUX AD
TYPE READ FAILED, port
OPTICAL MONITORING: INT UNMASK
ALL WRITE FAILED, port
OPTICAL MONITORING: INT MASK
WRITE FAILED, port
OPTICAL MONITORING:: OPTICAL
INT MASK WRITE FAILED, port
OPTICAL MONITORING: port
sys_create_timer failed
OPTICAL MONITORING: port
sys_create_timer2 failed
OPTICAL MONITORING: port
failed
OPTICAL MONITORING: port
latched flags(
OPTICAL MONITORING: port
failed