Chapter 2 Installation
2.3 How to Install
79
2.3.3 Installation of Rod Type
[1] Installation of Actuator Type Unit
There are two ways to install, one is to use the T-shaped slots on the frame and other to install
vertically with using the flange surface. The installed surface should be a machined surface or a
flat surface which possesses an equivalent accuracy to it, and the flatness should be 0.05mm at
the maximum.
See the appearance drawings for the details of the actuator dimensions. [Refer to Chapter 9]
(1) Mounting Method 1 (When using T slots on frame)
There are T-shaped slots on the frame for installation. Attach the unit directly with using these T
slots or use foot brackets (option).
Square nuts (4 pieces) for T-shaped slot are enclosed in standard.
• Direct Installation
Regarding attachment screws
Caution: Pay attention to the bolt length. It may cause an unexpected accident or failure due
to an insufficient attachment strength if the screws are too long or short.
Actuator
Type
Mounting
Screw
A
B
Tightening Torque
[N•m]
RA4C
M4
17
7
1.76
RA6C
M6
25
11.6
5.36
For RA4C
For RA6C
Square nut
䎥
䎃