Input and Output Response Performance When PIO

Converter is Used

389

Chapter 10 Appendix

10.1 Input and Output Response Performance When PIO Converter is Used

When controlling ERC3 with using PIO converter, there is a delay in the response time as described

below;

1) Input Delay Time of PIO Converter

The digital input time constant with the hardware is 2ms at maximum. The digital input filter time

with the firmware is 5ms at maximum. Therefore, there is 7ms of input response time in total for

PIO converter.

2) Communication Cycle Time (I/O Update Time) of PIO Converter

5ms at maximum is required for the communication cycle time of PIO converter under the

condition that there is no failure in the communication. The cycle time should be 10ms at

maximum with a communication error occurred.

3) Delay Time in Output Operation

There should be no delay time in the digital output operation of the firmware. It outputs the output

data received from ERC3 in communication cycle every time.

Considering the time described above, the timing for the input and output signals should be as

shown below;

PIO Converter Input

Delay Time 1) (MAX.7ms)

Communication Cycle Tim

2) (MAX.5ms)

ERC3 process time

Control signal

Status signal

Control signal

Status signal

Control signal

Status signal

Program on host controller

such as PLC

PIO converter

ERC3

PLC Input Delay Time

(depends on PLC settings)

PLC Input Delay Time

(depends on PLC settings)

Communication Cycle Tim

2) (MAX.5ms)

Communication Cycle Tim

2) (MAX.5ms)