Chapter 3 Wiring

3.5 MEC Mode 2 (Operation Using PIO Converter)

130

3.5 MEC Mode 2 (Operation Using PIO Converter)

3.5.1 Wiring Diagram (Connection of construction devices)

The model code for I/O type of ERC3 is SIO type (model code: SE).

Note 1 If Quick Teach is equipped with a power supply unit (100V type / 200V type / EU destination

type), remove the power supply unit.

The emergency stop input terminal is treated with short-circuit by a jumper. Remove the

jumper if necessary and connect devices such as an emergency stop switch (always closed

and open in emergency stop).

Note 2 ƑƑƑ indicates the cable length. (Example) 030 = 3m




MEC PC Software

(Download from homepage)

PLC

(Please prepare separately)

Teaching Pendant

(Please purchase separately)

I/O Flat Cable

CB-PAC-PIOƑƑƑ

(Note 1)

(enclosed in PIO Converter)

Quick Teach

(Note 1) (Note 2)

(Please purchase separately)

CB-PST-SIO050

(Optional casing for Quick Teach)

PIO Converter

Power Supply

Absolute Battery

AB-7

(For Simple Absolute Type)

ERC3 Accessory Cable

CB-ERC3S-PWBIOƑƑƑ

(Note 2)

24V DC