Chapter 4 Operation
4.5 Operation in MEC Mode 3 (T
est Run with Quick
Teach.)
277
[8] Switches and Rotary Knobs Used in Acceleration/Deceleration and Speed Settings
The speed to move and the acceleration/deceleration speed of the actuator to the forward,
backward and intermediate positions can be determined.
Twist Accel Dial and adjust at the desired
position. (Setting Range : 1 to 100%)
Registering
Acceleration/
Deceleration
(Valid in Manual
Mode)
Press SAVE Button. If the registration is
complete, a peep sound is made and the
save lamp turns ON.
(The setting is registered together with the
speed setting.)
Twist Speed Dial and adjust at the desired
position. (Setting Range : * to 100%)
(* It differs depending on the actuator.)
Registering Speed
(Valid in Manual
Mode)
Press SAVE Button. If the registration is
complete, a peep sound is made and the
save lamp turns ON.
(The setting is registered together with the
acceleration setting.)
[9] Switches Used in Test Run
Performing
Continuous Operation
(Valid in Manual
Mode)
Press RUN Button and a continuous
operation is started.
If set to 2-point positioning, the continuous
operation is performed in the order of end
point ĺ start point ĺ end point.
If set to 3-point positioning, the continuous
operation is performed in the order of
intermediate point ĺ end point ĺ start
point ĺ intermediate point.
The operation lamp flashes while in the
continuous operation.
Stopping Continuous
Operation
(Valid in Manual
Mode)
Press STOP Button and the operation
stops.
Once it is stopped, the stop lamp turns ON.
[10] Switches Used in Alarm Reset
Alarm Reset
(Valid in Manual
Mode)
Press and hold STOP button.
Reset the alarm.