Chapter 5 Power-saving Function (Automatic Servo-of

f and Full Servo Functions)

5.2 Pulse

Train Control Mode

290

5.2 Pulse Train Control Mode

Power saving cannot be performed with the automatic servo OFF. Only the full servo control

setting is available.

In the full servo function, the power consumption can be reduced by having a servo control to

save the current during a stop.

Servo-on complete after power

being supplied

(before positioning to target

position)

Home return completion

(before positioning to target

position)

St

op

Conditio

n

Positioning completion

Power saving function executed with the setting

held in Parameter No.53

Set of power-saving mode

Select a number from the conditions below and set it in Parameter No.53.

Set Value

Operation after completion of operation

0

Servo ON not changed

1

Servo ON not changed

2

Servo ON not changed

3

Servo ON not changed

4

Full servo control

5

Full servo control

6

Full servo control

7

Full servo control