Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

321

(28) Auto servo motor OFF delay time 1, 2, 3 (Parameter No.36, No.37, No.38)

No.

Name

Symbol

Unit

Input Range

Default factory setting

36

Auto servo motor OFF delay

time 1

ASO1

sec

0 to 9999

0

37

Auto servo motor OFF delay

time 2

ASO2

sec

0 to 9999

0

38

Auto servo motor OFF delay

time 3

ASO3

sec

0 to 9999

0

Set the duration before the servo turns OFF after positioning process is complete when the

power saving function is used.

[Refer to Chapter 5 Power-saving Function.]

(29) Position complete signal output method (Parameter No.39)

No.

Name

Symbol

Unit

Input Range

Default factory setting

39

Position complete signal

output method

FPIO

0: PEND

1: INP

0

It is valid when a mode other than PIO Pattern 1 = 3-point type [Solenoid Valve Type] in

Positioner Mode 1 and PIO Pattern = 5 (Solenoid Valve Type 2 [3-point type]) in Positioner

Mode 2 is being selected.

Select the type of positioning complete signal. There are two types of positioning complete

signals, PEND and INP, and the condition of being OFF differs for each type. Select the suitable

one considering the control method.

Check each control method for operation in “Chapter 4 Operation” for details.

Setting

Signal Name

Description

0

PEND

Ɣ Turns ON if in positioning complete condition

Ɣ Remains ON even if current position is out of

positioning width after positioning is complete

Ɣ Turns OFF during a pause no matter of

moving/stopping

Ɣ Turns OFF during servo-off with no exception

1

INP

Turns ON when current position is in the

positioning width of indicated position number, and

OFF when out of positioning width

Complete position No. outputs PM1 to PM** and current position No. outputs PE0 to PE6 are

issued in the similar way.

(30) Home-return input disable (Parameter No.40)

No.

Name

Symbol

Unit

Input Range

Default factory setting

40 Home-return input disable

FPIO

0 : Enabled

1 : Disabled

0

This parameter defines whether the home return input signal is disabled or enabled.

Normally this parameter need not be changed.

Set Value

Description

0

Enable (Use the input signal)

1

Disable (Does not use the input signal)